● It adopts embedded microcontroller technology and four digit LED display, which can be used together with various types of coal mine safety monitoring system and power-off instrument.
● It has the functions of local display, intermittent audible and visual alarm, adjustable alarm point, adjustable power off point and power restoration point, infrared remote control adjustment, etc.
● Standard frequency output, customized current, switching value and RS485 output.
Main technical parameters
Technical parameters |
|
||
Supply voltage |
DC( 9~24)V |
Output Signal |
Frequency: (200 ~ 1000) Hz; |
Measuring Range |
(0~25)%O2 |
Transmission Distance |
≥2km |
Response time |
<35s |
Explosion proof type |
Exib 1 MB |
Sensor life |
>2yr |
Sound level intensity |
>80db |
Resolving power |
0.1 |
Coal safety certificate number |
MFB090081 |